<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Portable Appliance Testing Specialist</title>
	<atom:link href="http://www.pattest4u.com/feed" rel="self" type="application/rss+xml" />
	<link>http://www.pattest4u.com</link>
	<description>Darlington &#124; Bishop Auckland &#124; Durham &#124; Richmond &#124; Hartlepool</description>
	<lastBuildDate>Mon, 25 Jul 2011 18:22:54 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.2.1</generator>
		<item>
		<title>Landlords and Portable Appliance Testing</title>
		<link>http://www.pattest4u.com/07/faq/landlords-and-portable-appliance-testing</link>
		<comments>http://www.pattest4u.com/07/faq/landlords-and-portable-appliance-testing#comments</comments>
		<pubDate>Mon, 25 Jul 2011 18:22:54 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[FAQ]]></category>

		<guid isPermaLink="false">http://www.pattest4u.com/?p=222</guid>
		<description><![CDATA[]]></description>
			<content:encoded><![CDATA[]]></content:encoded>
			<wfw:commentRss>http://www.pattest4u.com/07/faq/landlords-and-portable-appliance-testing/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Special Rates for Charities, Community and Voluntary Organisation&#8217;s</title>
		<link>http://www.pattest4u.com/07/faq/special-rates-for-charities-community-and-voluntary-organisations</link>
		<comments>http://www.pattest4u.com/07/faq/special-rates-for-charities-community-and-voluntary-organisations#comments</comments>
		<pubDate>Mon, 25 Jul 2011 17:44:48 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[FAQ]]></category>
		<category><![CDATA[Cost]]></category>
		<category><![CDATA[Price]]></category>

		<guid isPermaLink="false">http://www.pattest4u.com/?p=175</guid>
		<description><![CDATA[PATtest4U™ are proud to be able to offer registered charities, community groups and voluntary organisation a special discounted rate on all their Portable Appliance Testing requirements, just ask for more information.]]></description>
			<content:encoded><![CDATA[<p><strong>PATtest4U™</strong> are proud to be able to offer registered charities, community groups and voluntary organisation a special discounted rate on all their <strong>Portable Appliance Testing</strong> requirements, just ask for more information.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.pattest4u.com/07/faq/special-rates-for-charities-community-and-voluntary-organisations/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Do you have more PAT Testing questions?</title>
		<link>http://www.pattest4u.com/07/faq/do-you-have-more-pat-testing-questions</link>
		<comments>http://www.pattest4u.com/07/faq/do-you-have-more-pat-testing-questions#comments</comments>
		<pubDate>Mon, 25 Jul 2011 17:38:56 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[FAQ]]></category>
		<category><![CDATA[PAT Testing]]></category>
		<category><![CDATA[Questions]]></category>

		<guid isPermaLink="false">http://www.pattest4u.com/?p=168</guid>
		<description><![CDATA[If you still have question about Portable Appliance Testing [PAT testing] please call us and one of our staff will be more than willing to assist you.]]></description>
			<content:encoded><![CDATA[<div id="attachment_169" class="wp-caption alignright" style="width: 200px"><a href="http://www.pattest4u.com/wp-content/uploads/2011/07/faq.jpg"><img class="size-full wp-image-169" title="Portable Appliance Testing FAQ" src="http://www.pattest4u.com/wp-content/uploads/2011/07/faq.jpg" alt="Portable Appliance Testing FAQ" width="190" height="106" /></a><p class="wp-caption-text">Portable Appliance Testing FAQ</p></div>
<p>If you still have question about <strong>Portable Appliance Testing</strong> [<abbr title="Portable Appliance Testing" lang="gb">PAT</abbr> testing] please call us and one of our staff will be more than willing to assist you.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.pattest4u.com/07/faq/do-you-have-more-pat-testing-questions/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>What are Portable Appliances?</title>
		<link>http://www.pattest4u.com/07/faq/what-are-portable-appliances</link>
		<comments>http://www.pattest4u.com/07/faq/what-are-portable-appliances#comments</comments>
		<pubDate>Mon, 25 Jul 2011 17:33:50 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[FAQ]]></category>
		<category><![CDATA[Portable Appliances]]></category>

		<guid isPermaLink="false">http://www.pattest4u.com/?p=161</guid>
		<description><![CDATA[]]></description>
			<content:encoded><![CDATA[]]></content:encoded>
			<wfw:commentRss>http://www.pattest4u.com/07/faq/what-are-portable-appliances/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>What is Portable Appliance Testing aka PAT Testing?</title>
		<link>http://www.pattest4u.com/07/faq/what-is-portable-appliance-testing-aka-pat-testing</link>
		<comments>http://www.pattest4u.com/07/faq/what-is-portable-appliance-testing-aka-pat-testing#comments</comments>
		<pubDate>Mon, 25 Jul 2011 17:19:02 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[FAQ]]></category>
		<category><![CDATA[PAT Testing]]></category>
		<category><![CDATA[What Is?]]></category>

		<guid isPermaLink="false">http://www.pattest4u.com/?p=145</guid>
		<description><![CDATA[Portable Appliance Testing (PAT) is an important part of a company&#8217;s or individual&#8217;s responsibility to health and safety. This is done using a series of specialised testing procedures on your portable appliances.]]></description>
			<content:encoded><![CDATA[<p><strong>Portable Appliance Testing</strong> (<acronym title="Portable Appliance Testing" lang="gb">PAT</acronym>) is an important part of a company&#8217;s or individual&#8217;s responsibility to health and safety. This is done using a series of specialised testing procedures on your portable appliances.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.pattest4u.com/07/faq/what-is-portable-appliance-testing-aka-pat-testing/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Frequency of inspection &amp; testing of equipment for Offices and Shops</title>
		<link>http://www.pattest4u.com/07/testing-frequency/frequency-of-inspection-testing-of-equipment-for-offices-and-shops</link>
		<comments>http://www.pattest4u.com/07/testing-frequency/frequency-of-inspection-testing-of-equipment-for-offices-and-shops#comments</comments>
		<pubDate>Sun, 24 Jul 2011 20:50:34 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Testing Frequency]]></category>
		<category><![CDATA[Office]]></category>
		<category><![CDATA[Shop]]></category>

		<guid isPermaLink="false">http://www.pattest4u.com/?p=130</guid>
		<description><![CDATA[PATtest4U™ are specialists in the field of Portable Appliance Testing and always use The Institute of Electrical Engineers (IEE) suggested initial frequency of inspection and testing of equipment, as published in their Code of Practice for In-service Inspection and Testing of Electrical Equipment as a guide to their inspection and testing frequency. The information on [...]]]></description>
			<content:encoded><![CDATA[<p><strong></strong><strong>PATtest4U™</strong> are specialists in the field of <strong>Portable Appliance Testing</strong> and always use The <strong>Institute of Electrical Engineers</strong> (I<acronym title="Institute of Electrical Engineers" lang="gb">EE</acronym>) suggested initial frequency of inspection and testing of equipment, as published in their <strong>Code of Practice for In-service Inspection and Testing of Electrical Equipment</strong> as a guide to their inspection and testing frequency.</p>
<p>The information on the suggested initial frequencies given below is more detailed and specific that the Health &amp; Safety Executive (<acronym title="Health and Safety Executice" lang="gb">HSE</acronym>) guidance, but is not considered to be inconsistent with it.</p>
<p>The following is the IEE&#8217;s Code of Practice for In-service Inspection and Testing of Electrical Equipment suggested initial frequency of inspection and testing of equipment for <strong>Offices and Shops</strong>.</p>
<table id="mytable" summary="Schools" cellspacing="0">
<caption>Initial frequency of inspection and testing of equipment: Offices and Shops</caption>
<tbody>
<tr>
<th class="nobg" scope="col" width="%">Type of Equipment</th>
<th scope="col" width="">
<div align="center">User Checks</div>
</th>
<th scope="col" width="18%">
<div align="center">Class I Formal Visual Inspection<br />
(<a href="http://www.pattest4u.com/07/testing-frequency/note-1-initial-frequencies-o-inspection-testing">Note 1</a>)</div>
</th>
<th scope="col" width="18%">
<div align="center">Class I Combined Inspection &amp; Testing</div>
</th>
<th scope="col" width="18%">
<div align="center">Class II Formal Visual Inspection<br />
(<a href="http://www.pattest4u.com/07/testing-frequency/note-1-initial-frequencies-o-inspection-testing">Note 1</a>)</div>
</th>
<th scope="col" width="18%">
<div align="center">Class II Combined Inspection &amp; Testing</div>
</th>
</tr>
<tr>
<th class="spec" scope="row">Stationery</th>
<td>
<div align="center">None</div>
</td>
<td>
<div align="center">24 Months</div>
</td>
<td>
<div align="center">48 Months</div>
</td>
<td>
<div align="center">24 Months</div>
</td>
<td>
<div align="center">None</div>
</td>
</tr>
<tr>
<th class="specalt" scope="row">Information Technology</th>
<td class="alt">
<div align="center">None</div>
</td>
<td class="alt">
<div align="center">24 Months</div>
</td>
<td class="alt">
<div align="center">48 Months</div>
</td>
<td class="alt">
<div align="center">24 Months</div>
</td>
<td class="alt">
<div align="center">None</div>
</td>
</tr>
<tr>
<th class="spec" scope="row">Moveable</th>
<td>
<div align="center">Weekly</div>
</td>
<td>
<div align="center">12 Months</div>
</td>
<td>
<div align="center">24 Months</div>
</td>
<td>
<div align="center">24 Months</div>
</td>
<td>
<div align="center">None</div>
</td>
</tr>
<tr>
<th class="specalt" scope="row">Portable</th>
<td class="alt">
<div align="center">Weekly</div>
</td>
<td class="alt">
<div align="center">12 Months</div>
</td>
<td class="alt">
<div align="center">24 Months</div>
</td>
<td class="alt">
<div align="center">24 Months</div>
</td>
<td class="alt">
<div align="center">None</div>
</td>
</tr>
<tr>
<th class="spec" scope="row">Hand-held<a title="Note 4 – Initial frequencies of inspection &amp; testing" href="http://www.pattest4u.com/07/testing-frequency/note-4-initial-frequencies-of-inspection-testing"><br />
</a></th>
<td>
<div align="center">Before Use</div>
</td>
<td>
<div align="center">6 Months</div>
</td>
<td>
<div align="center">12 Months</div>
</td>
<td>
<div align="center">6 Months</div>
</td>
<td style="text-align: center;">None</td>
</tr>
</tbody>
</table>
<p>Please be advised of the various notes associated with the above-mentioned table.</p>
<h3>Frequency of inspection and testing</h3>
<p>The relevant requirement of the Electricity at Work Regulations 1989 is that equipment shall be maintained so as to prevent danger.  Inspection and testing are means of determining whether maintenance is required. The frequency of inspection and testing will depend upon the likelihood of maintenance being required and the consequence of lack of maintenance.  No rigid guideline can be laid down, but factors influencing the decision include the following:</p>
<ul>
<li><strong>The environment</strong> &#8211; equipment installed in a benign environment, such as an office, will suffer less damage than equipment in an arduous environment, such as a construction site.</li>
<li><strong> The users &#8211; </strong>if the users of equipment report damage as and when it becomes evident, hazards will be avoided.  Conversely, if equipment is likely to receive unreported abuse, more frequent inspection and testing are required.</li>
<li><strong>The equipment construction</strong> -  the</li>
<li><strong>The equipment type</strong> &#8211; an</li>
</ul>
<p><strong>Source:</strong> <em>Code of Practice for In-Service Inspection and Testing of Electrical Equipment</em></p>
]]></content:encoded>
			<wfw:commentRss>http://www.pattest4u.com/07/testing-frequency/frequency-of-inspection-testing-of-equipment-for-offices-and-shops/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Frequency of inspection &amp; testing of equipment for Hotels</title>
		<link>http://www.pattest4u.com/07/testing-frequency/frequency-of-inspection-testing-of-equipment-for-hotels</link>
		<comments>http://www.pattest4u.com/07/testing-frequency/frequency-of-inspection-testing-of-equipment-for-hotels#comments</comments>
		<pubDate>Sun, 24 Jul 2011 20:46:58 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Testing Frequency]]></category>
		<category><![CDATA[Hotels]]></category>

		<guid isPermaLink="false">http://www.pattest4u.com/?p=128</guid>
		<description><![CDATA[PATtest4U™ are specialists in the field of Portable Appliance Testing and always use The Institute of Electrical Engineers (IEE) suggested initial frequency of inspection and testing of equipment, as published in their Code of Practice for In-service Inspection and Testing of Electrical Equipment. The information on the suggested initial frequencies given below is more detailed [...]]]></description>
			<content:encoded><![CDATA[<p><strong>PATtest4U™</strong> are specialists in the field of <strong>Portable Appliance Testing</strong> and always use The Institute of Electrical Engineers (I<acronym title="Institute of Electrical Engineers" lang="gb">EE</acronym>) suggested initial frequency of inspection and testing of equipment, as published in their Code of Practice for In-service Inspection and Testing of Electrical Equipment.</p>
<p>The information on the suggested initial frequencies given below is more detailed and specific that the Health &amp; Safety Executive (<acronym title="Health and Safety Executice" lang="gb">HSE</acronym>) guidance, but is not considered to be inconsistent with it.</p>
<p>The following is the IEE&#8217;s Code of Practice for In-service Inspection and Testing of Electrical Equipment suggested initial frequency of inspection and testing of equipment for <strong>Hotels</strong>.</p>
<table id="mytable" summary="Schools" cellspacing="0">
<caption>Initial frequency of inspection and testing of equipment: Hotels</caption>
<tbody>
<tr>
<th class="nobg" scope="col" width="%">Type of Equipment</th>
<th scope="col" width="">
<div align="center">User Checks</div>
</th>
<th scope="col" width="18%">
<div align="center">Class I Formal Visual Inspection<br />
(<a href="http://www.pattest4u.com/07/testing-frequency/note-1-initial-frequencies-o-inspection-testing">Note 1</a>)</div>
</th>
<th scope="col" width="18%">
<div align="center">Class I Combined Inspection &amp; Testing</div>
</th>
<th scope="col" width="18%">
<div align="center">Class II Formal Visual Inspection<br />
(<a href="http://www.pattest4u.com/07/testing-frequency/note-1-initial-frequencies-o-inspection-testing">Note 1</a>)</div>
</th>
<th scope="col" width="18%">
<div align="center">Class II Combined Inspection &amp; Testing</div>
</th>
</tr>
<tr>
<th class="spec" scope="row">Stationery (<a title="Note 5 – Initial frequencies of inspection &amp; testing" href="http://www.pattest4u.com/07/testing-frequency/note-5-initial-frequencies-of-inspection-testing">Note 5</a>)</th>
<td>
<div align="center">None</div>
</td>
<td>
<div align="center">24 Months</div>
</td>
<td>
<div align="center">48 Months</div>
</td>
<td>
<div align="center">24 Months</div>
</td>
<td>
<div align="center">None</div>
</td>
</tr>
<tr>
<th class="specalt" scope="row">Information Technology (<a title="Note 5 – Initial frequencies of inspection &amp; testing" href="http://www.pattest4u.com/07/testing-frequency/note-5-initial-frequencies-of-inspection-testing">Note 5</a>)</th>
<td class="alt">
<div align="center">None</div>
</td>
<td class="alt">
<div align="center">24 Months</div>
</td>
<td class="alt">
<div align="center">48 Months</div>
</td>
<td class="alt">
<div align="center">24 Months</div>
</td>
<td class="alt">
<div align="center">None</div>
</td>
</tr>
<tr>
<th class="spec" scope="row">Moveable (<a title="Note 5 – Initial frequencies of inspection &amp; testing" href="http://www.pattest4u.com/07/testing-frequency/note-5-initial-frequencies-of-inspection-testing">Note 5</a>)</th>
<td>
<div align="center">Weekly</div>
</td>
<td>
<div align="center">12 Months</div>
</td>
<td>
<div align="center">24 Months</div>
</td>
<td>
<div align="center">24 Months</div>
</td>
<td>
<div align="center">None</div>
</td>
</tr>
<tr>
<th class="specalt" scope="row">Portable <span class="spec">(<a title="Note 5 – Initial frequencies of inspection &amp; testing" href="http://www.pattest4u.com/07/testing-frequency/note-5-initial-frequencies-of-inspection-testing">Note 5</a>)</span></th>
<td class="alt">
<div align="center">Weekly</div>
</td>
<td class="alt">
<div align="center">12 Months</div>
</td>
<td class="alt">
<div align="center">24 Months</div>
</td>
<td class="alt">
<div align="center">24 Months</div>
</td>
<td class="alt">
<div align="center">None</div>
</td>
</tr>
<tr>
<th class="spec" scope="row">Hand-held (<a title="Note 5 – Initial frequencies of inspection &amp; testing" href="http://www.pattest4u.com/07/testing-frequency/note-5-initial-frequencies-of-inspection-testing">Note 5</a>)</th>
<td>
<div align="center">Before Use</div>
</td>
<td>
<div align="center">6 Months</div>
</td>
<td>
<div align="center">12 Months</div>
</td>
<td>
<div align="center">6 Months</div>
</td>
<td>
<div align="center">None</div>
</td>
</tr>
</tbody>
</table>
<p>Please be advised of the various notes associated with the following table.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.pattest4u.com/07/testing-frequency/frequency-of-inspection-testing-of-equipment-for-hotels/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Frequency of inspection &amp; testing of equipment for Schools</title>
		<link>http://www.pattest4u.com/07/testing-frequency/frequency-of-inspection-testing-of-equipment-for-schools</link>
		<comments>http://www.pattest4u.com/07/testing-frequency/frequency-of-inspection-testing-of-equipment-for-schools#comments</comments>
		<pubDate>Sun, 24 Jul 2011 20:42:46 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Testing Frequency]]></category>
		<category><![CDATA[Schools]]></category>

		<guid isPermaLink="false">http://www.pattest4u.com/?p=126</guid>
		<description><![CDATA[PATtest4U™ are specialists in the field of Portable Appliance Testing and always use The Institute of Electrical Engineers (IEE) suggested initial frequency of inspection and testing of equipment, as published in their Code of Practice for In-service Inspection and Testing of Electrical Equipment. The information on the suggested initial frequencies given below is more detailed [...]]]></description>
			<content:encoded><![CDATA[<p><strong>PATtest4U™</strong> are specialists in the field of <strong>Portable Appliance Testing</strong> and always use The Institute of Electrical Engineers (I<acronym title="Institute of Electrical Engineers" lang="gb">EE</acronym>) suggested initial frequency of inspection and testing of equipment, as published in their Code of Practice for In-service Inspection and Testing of Electrical Equipment.</p>
<p>The information on the suggested initial frequencies given below is more detailed and specific that the Health &amp; Safety Executive (<acronym title="Health and Safety Executice" lang="gb">HSE</acronym>) guidance, but is not considered to be inconsistent with it.</p>
<p>The following is the IEE&#8217;s Code of Practice for In-service Inspection and Testing of Electrical Equipment suggested initial frequency of inspection and testing of equipment for <strong>Schools</strong>.</p>
<table id="mytable" summary="Schools" cellspacing="0">
<caption>Initial frequency of inspection and testing of equipment: Schools</caption>
<tbody>
<tr>
<th class="nobg" scope="col" width="%">Type of Equipment</th>
<th scope="col" width="">
<div align="center">User Checks</div>
</th>
<th scope="col" width="18%">
<div align="center">Class I Formal Visual Inspection<br />
(<a href="http://www.pattest4u.com/07/testing-frequency/note-1-initial-frequencies-o-inspection-testing">Note 1</a>)</div>
</th>
<th scope="col" width="18%">
<div align="center">Class I Combined Inspection &amp; Testing</div>
</th>
<th scope="col" width="18%">
<div align="center">Class II Formal Visual Inspection<br />
(<a href="http://www.pattest4u.com/07/testing-frequency/note-1-initial-frequencies-o-inspection-testing">Note 1</a>)</div>
</th>
<th scope="col" width="18%">
<div align="center">Class II Combined Inspection &amp; Testing</div>
</th>
</tr>
<tr>
<th class="spec" scope="row">Stationery (<a title="Note 4 – Initial frequencies of inspection &amp; testing" href="http://www.pattest4u.com/07/testing-frequency/note-4-initial-frequencies-of-inspection-testing">Note 4</a>)</th>
<td>
<div align="center">Weekly</div>
</td>
<td>
<div align="center">None</div>
</td>
<td>
<div align="center">12 Months</div>
</td>
<td>
<div align="center">12 Months</div>
</td>
<td>
<div align="center">48 Months</div>
</td>
</tr>
<tr>
<th class="specalt" scope="row">Information Technology (<a title="Note 4 – Initial frequencies of inspection &amp; testing" href="http://www.pattest4u.com/07/testing-frequency/note-4-initial-frequencies-of-inspection-testing">Note 4</a>)</th>
<td class="alt">
<div align="center">Weekly</div>
</td>
<td class="alt">
<div align="center">None</div>
</td>
<td class="alt">
<div align="center">12 Months</div>
</td>
<td class="alt">
<div align="center">12 Months</div>
</td>
<td class="alt">
<div align="center">48 Months</div>
</td>
</tr>
<tr>
<th class="spec" scope="row">Moveable (<a title="Note 4 – Initial frequencies of inspection &amp; testing" href="http://www.pattest4u.com/07/testing-frequency/note-4-initial-frequencies-of-inspection-testing">Note 4</a>)</th>
<td>
<div align="center">Weekly</div>
</td>
<td>
<div align="center">4 Months</div>
</td>
<td>
<div align="center">12 Months</div>
</td>
<td>
<div align="center">4 Months</div>
</td>
<td>
<div align="center">48 Months</div>
</td>
</tr>
<tr>
<th class="specalt" scope="row">Portable <span class="spec">(<a title="Note 4 – Initial frequencies of inspection &amp; testing" href="http://www.pattest4u.com/07/testing-frequency/note-4-initial-frequencies-of-inspection-testing">Note 4</a>)</span></th>
<td class="alt">
<div align="center">Weekly</div>
</td>
<td class="alt">
<div align="center">4 Months</div>
</td>
<td class="alt">
<div align="center">12 Months</div>
</td>
<td class="alt">
<div align="center">4 Months</div>
</td>
<td class="alt">
<div align="center">48 Months</div>
</td>
</tr>
<tr>
<th class="spec" scope="row">Hand-held (<a title="Note 4 – Initial frequencies of inspection &amp; testing" href="http://www.pattest4u.com/07/testing-frequency/note-4-initial-frequencies-of-inspection-testing">Note 4</a>)</th>
<td>
<div align="center">Before Use</div>
</td>
<td>
<div align="center">4 Months</div>
</td>
<td>
<div align="center">12 Months</div>
</td>
<td>
<div align="center">4 Months</div>
</td>
<td>
<div align="center">48 Months</div>
</td>
</tr>
</tbody>
</table>
<p>Please be advised of the various notes associated with the following table.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.pattest4u.com/07/testing-frequency/frequency-of-inspection-testing-of-equipment-for-schools/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Equipment used by the public testing frequency</title>
		<link>http://www.pattest4u.com/07/testing-frequency/equipment-used-by-the-public-testing-frequency</link>
		<comments>http://www.pattest4u.com/07/testing-frequency/equipment-used-by-the-public-testing-frequency#comments</comments>
		<pubDate>Sun, 24 Jul 2011 20:34:09 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Testing Frequency]]></category>
		<category><![CDATA[Public]]></category>

		<guid isPermaLink="false">http://www.pattest4u.com/?p=120</guid>
		<description><![CDATA[PATtest4U™ are specialists in the field of Portable Appliance Testing and always use The Institute of Electrical Engineers (IEE) suggested initial frequency of inspection and testing of equipment, as published in their Code of Practice for In-service Inspection and Testing of Electrical Equipment. The information on the suggested initial frequencies given below is more detailed [...]]]></description>
			<content:encoded><![CDATA[<p><strong>PATtest4U™</strong> are specialists in the field of <strong>Portable Appliance Testing</strong> and always use The Institute of Electrical Engineers (I<acronym title="Institute of Electrical Engineers" lang="gb">EE</acronym>) suggested initial frequency of inspection and testing of equipment, as published in their Code of Practice for In-service Inspection and Testing of Electrical Equipment.</p>
<p>The information on the suggested initial frequencies given below is more detailed and specific that the Health &amp; Safety Executive (<acronym title="Health and Safety Executice" lang="gb">HSE</acronym>) guidance, but is not considered to be inconsistent with it.</p>
<p>The following is the IEE&#8217;s Code of Practice for In-service Inspection and Testing of Electrical Equipment suggested initial frequency of inspection and testing of equipment for <strong>Equipment used by the Public</strong>.</p>
<table id="mytable" summary="Initial frequency of inspection and testing of equipment: Equipment used by the Public" cellspacing="0">
<caption>Initial frequency of inspection and testing of equipment: Equipment used by the Public</caption>
<tbody>
<tr>
<th class="nobg" scope="col" width="%">Type of Equipment</th>
<th scope="col" width="">
<div align="center">User Checks</div>
</th>
<th scope="col" width="18%">
<div align="center">Class I Formal Visual Inspection<br />
(<a href="http://www.pattest4u.com/07/testing-frequency/note-1-initial-frequencies-o-inspection-testing">Note 1</a>)</div>
</th>
<th scope="col" width="18%">
<div align="center">Class I Combined Inspection &amp; Testing</div>
</th>
<th scope="col" width="18%">
<div align="center">Class II Formal Visual Inspection (<a href="http://www.pattest4u.com/07/testing-frequency/note-1-initial-frequencies-o-inspection-testing">Note 1</a>)</div>
</th>
<th scope="col" width="18%">
<div align="center">Class II Combined Inspection &amp; Testing</div>
</th>
</tr>
<tr>
<th class="spec" scope="row">Stationery</th>
<td style="text-align: center;">(<a title="Note 3 – Initial frequencies of inspection &amp; testing" href="http://www.pattest4u.com/07/testing-frequency/note-3-initial-frequencies-of-inspection-testing">Note 3</a>, <a title="Note 4 – Initial frequencies of inspection &amp; testing" href="http://www.pattest4u.com/07/testing-frequency/note-4-initial-frequencies-of-inspection-testing">Note 4</a>)</td>
<td>
<div align="center">Monthly</div>
</td>
<td>
<div align="center">12 Months</div>
</td>
<td>
<div align="center">3 Months</div>
</td>
<td>
<div align="center">12 Months</div>
</td>
</tr>
<tr>
<th class="specalt" scope="row">Information Technology</th>
<td class="alt">
<div align="center">(<a title="Note 3 – Initial frequencies of inspection &amp; testing" href="http://www.pattest4u.com/07/testing-frequency/note-3-initial-frequencies-of-inspection-testing">Note 3</a>, <a title="Note 4 – Initial frequencies of inspection &amp; testing" href="http://www.pattest4u.com/07/testing-frequency/note-4-initial-frequencies-of-inspection-testing">Note 4</a>)</div>
</td>
<td class="alt">
<div align="center">Monthly</div>
</td>
<td class="alt">
<div align="center">12 Months</div>
</td>
<td class="alt">
<div align="center">3 Months</div>
</td>
<td class="alt">
<div align="center">12 Months</div>
</td>
</tr>
<tr>
<th class="spec" scope="row">Moveable</th>
<td>
<div align="center">(<a title="Note 3 – Initial frequencies of inspection &amp; testing" href="http://www.pattest4u.com/07/testing-frequency/note-3-initial-frequencies-of-inspection-testing">Note 3</a>, <a title="Note 4 – Initial frequencies of inspection &amp; testing" href="http://www.pattest4u.com/07/testing-frequency/note-4-initial-frequencies-of-inspection-testing">Note 4</a>)</div>
</td>
<td>
<div align="center">Weekly</div>
</td>
<td>
<div align="center">6 Months</div>
</td>
<td>
<div align="center">1 Month</div>
</td>
<td>
<div align="center">12 Months</div>
</td>
</tr>
<tr>
<th class="specalt" scope="row">Portable</th>
<td class="alt">
<div align="center">(<a title="Note 3 – Initial frequencies of inspection &amp; testing" href="http://www.pattest4u.com/07/testing-frequency/note-3-initial-frequencies-of-inspection-testing">Note 3</a>, <a title="Note 4 – Initial frequencies of inspection &amp; testing" href="http://www.pattest4u.com/07/testing-frequency/note-4-initial-frequencies-of-inspection-testing">Note 4</a>)</div>
</td>
<td class="alt">
<div align="center">Weekly</div>
</td>
<td class="alt">
<div align="center">6 Months</div>
</td>
<td class="alt">
<div align="center">1 Month</div>
</td>
<td class="alt">
<div align="center">12 Months</div>
</td>
</tr>
<tr>
<th class="spec" scope="row">Hand-held</th>
<td style="text-align: center;">(<a title="Note 3 – Initial frequencies of inspection &amp; testing" href="http://www.pattest4u.com/07/testing-frequency/note-3-initial-frequencies-of-inspection-testing">Note 3</a>, <a title="Note 4 – Initial frequencies of inspection &amp; testing" href="http://www.pattest4u.com/07/testing-frequency/note-4-initial-frequencies-of-inspection-testing">Note 4</a>)</td>
<td>
<div align="center">Weekly</div>
</td>
<td>
<div align="center">6 Months</div>
</td>
<td>
<div align="center">1 Month</div>
</td>
<td>
<div align="center">12 Months</div>
</td>
</tr>
</tbody>
</table>
<p>Please be advised of the various notes associated with the following table.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.pattest4u.com/07/testing-frequency/equipment-used-by-the-public-testing-frequency/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Note 5 &#8211; Initial frequencies of inspection &amp; testing</title>
		<link>http://www.pattest4u.com/07/testing-frequency/note-5-initial-frequencies-of-inspection-testing</link>
		<comments>http://www.pattest4u.com/07/testing-frequency/note-5-initial-frequencies-of-inspection-testing#comments</comments>
		<pubDate>Sun, 24 Jul 2011 18:46:22 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Testing Frequency]]></category>
		<category><![CDATA[Note 5]]></category>

		<guid isPermaLink="false">http://www.pattest4u.com/?p=116</guid>
		<description><![CDATA[Equipment provided in hotel rooms is equipment used by the public and should be inspected and tested in accordance with Equipment used by the Public.  The frequencies given on the Hotels page is for equipment used by Hotel staff (excludes commercial kitchen which comes under Industrial including Commercial Kitchens.]]></description>
			<content:encoded><![CDATA[<p>Equipment provided in hotel rooms is equipment used by the public and should be inspected and tested in accordance with Equipment used by the Public.  The frequencies given on the Hotels page is for equipment used by Hotel staff (excludes commercial kitchen which comes under Industrial including Commercial Kitchens.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.pattest4u.com/07/testing-frequency/note-5-initial-frequencies-of-inspection-testing/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

